Raw JSON
{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NON_RANDOMIZED', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'OTHER', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 200}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2024-01-01', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2024-09', 'completionDateStruct': {'date': '2024-05-15', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2024-09-07', 'studyFirstSubmitDate': '2024-09-07', 'studyFirstSubmitQcDate': '2024-09-07', 'lastUpdatePostDateStruct': {'date': '2024-09-19', 'type': 'ACTUAL'}, 'studyFirstPostDateStruct': {'date': '2024-09-19', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2024-01-20', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'heart rate', 'timeFrame': '5 months', 'description': 'heart rate in beats'}, {'measure': 'peripheral oxygen saturation', 'timeFrame': '5 months', 'description': 'peripheral oxygen saturation in percentage'}], 'secondaryOutcomes': [{'measure': 'weight', 'timeFrame': '5 months', 'description': 'weight in kilograms'}, {'measure': 'height', 'timeFrame': '5 months', 'description': 'height in meters'}]}, 'oversightModule': {'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': False}, 'conditionsModule': {'keywords': ['Body Positions', 'Oxygenation', 'Pulse Oximetry'], 'conditions': ['Peripheral Oxygen Saturation', 'Healthy Individuals']}, 'descriptionModule': {'briefSummary': 'This study aims to examine peripheral oxygen saturation values measured in different body positions and fingers in healthy young adult individuals.\n\nThe research was planned in a quasi-experimental design. The research population consisted of students/healthy young adults studying at Bursa Uludağ University Faculty of Health Sciences between January 2024 and May 2024. The research sample consisted of a total of 200 volunteer individuals who met the research limitations.\n\nThe research data were collected using the Individual Introduction Form and Peripheral Oxygen Saturation Monitoring Form. A pulse oximeter was placed simultaneously on the index and middle fingers of each participant\\'s active hand while they were in an upright sitting position. After the pulse oximeter was placed on both fingers for one minute, stable values seen on its screen for at least three seconds were recorded. Then, the participants were placed in a supine position, and after a 10-minute rest, similar measurements were repeated with a pulse oximeter placed on the index and middle fingers of the active hand.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT'], 'maximumAge': '35 Years', 'minimumAge': '19 Years', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* participating voluntarily in the study\n* being aged over 18 years\n* not having any acute or chronic disease\n\nExclusion Criteria:\n\n* being less than 18 years of age,\n* having anemia,\n* not wanting to participate in the study, or during the course of the research, wishing to withdraw from the study,\n* having an oxygen saturation value of less than 90%,\n* being unable to tolerate a 0° prone position (bradycardic).'}, 'identificationModule': {'nctId': 'NCT06591403', 'briefTitle': 'INVESTIGATION OF PERIPHERAL OXYGEN SATURATION VALUES MEASURED IN DIFFERENT BODY POSITIONS AND FINGERS IN HEALTHY YOUNG ADULT INDIVIDUALS', 'organization': {'class': 'OTHER', 'fullName': 'Uludag University'}, 'officialTitle': 'INVESTIGATION OF PERIPHERAL OXYGEN SATURATION VALUES MEASURED IN DIFFERENT BODY POSITIONS AND FINGERS', 'orgStudyIdInfo': {'id': '2023-25/25'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'the different body positions and fingers', 'interventionNames': ['Other: the index and middle fingers of each participant's active hand']}], 'interventions': [{'name': 'the index and middle fingers of each participant's active hand', 'type': 'OTHER', 'description': 'A pulse oximeter was placed simultaneously on the index and middle fingers of each participants active hand while they were in an upright sitting position. After the pulse oximeter was placed on both fingers for one minute, stable values seen on its screen for at least three seconds were recorded. Then, the participants were placed in a supine position, and after a 10-minute rest, similar measurements were repeated with a pulse oximeter placed on the index and middle fingers of the active hand.', 'armGroupLabels': ['the different body positions and fingers']}]}, 'contactsLocationsModule': {'locations': [{'zip': '16059', 'city': 'Bursa', 'state': 'Nilüfer', 'country': 'Turkey (Türkiye)', 'facility': 'Bursa Uludag University Faculty of Health Sciences', 'geoPoint': {'lat': 40.19559, 'lon': 29.06013}}]}, 'ipdSharingStatementModule': {'ipdSharing': 'UNDECIDED'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Uludag University', 'class': 'OTHER'}, 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'Associate Professor', 'investigatorFullName': 'Dilek Yilmaz, PhD', 'investigatorAffiliation': 'Uludag University'}}}}