Viewing Study NCT02162004


Ignite Creation Date: 2025-12-24 @ 9:12 PM
Ignite Modification Date: 2026-01-18 @ 6:23 PM
Study NCT ID: NCT02162004
Status: TERMINATED
Last Update Posted: 2016-08-31
First Post: 2014-06-02
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: Continuous Correction
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D003922', 'term': 'Diabetes Mellitus, Type 1'}], 'ancestors': [{'id': 'D003920', 'term': 'Diabetes Mellitus'}, {'id': 'D044882', 'term': 'Glucose Metabolism Disorders'}, {'id': 'D008659', 'term': 'Metabolic Diseases'}, {'id': 'D009750', 'term': 'Nutritional and Metabolic Diseases'}, {'id': 'D004700', 'term': 'Endocrine System Diseases'}, {'id': 'D001327', 'term': 'Autoimmune Diseases'}, {'id': 'D007154', 'term': 'Immune System Diseases'}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'RANDOMIZED', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'TREATMENT', 'interventionModel': 'CROSSOVER'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 2}}, 'statusModule': {'whyStopped': 'Technical problems', 'overallStatus': 'TERMINATED', 'startDateStruct': {'date': '2014-06'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2015-02', 'completionDateStruct': {'date': '2014-12', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2016-08-30', 'studyFirstSubmitDate': '2014-06-02', 'studyFirstSubmitQcDate': '2014-06-10', 'lastUpdatePostDateStruct': {'date': '2016-08-31', 'type': 'ESTIMATED'}, 'studyFirstPostDateStruct': {'date': '2014-06-12', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2014-12', 'type': 'ACTUAL'}}, 'outcomesModule': {'otherOutcomes': [{'measure': 'Mean absolute relative difference.', 'timeFrame': 'Every 5 min for 9 hours on each study day.', 'description': 'CGM accuracy will be evaluated with Hemocue glucose values as reference (mean absolute relative difference).'}], 'primaryOutcomes': [{'measure': 'Percentage of time CGM values are in the target range 3.9-8.0 mmol/l in the time period 8:00-17:00.', 'timeFrame': 'Every 5 min for 9 hours on each study day.', 'description': 'The primary outcome is difference in the percentage of time CGM values are in the target range 3.9-8.0 mmol/l in the time period 8:00-17:00 on CC-days and Control-days.'}], 'secondaryOutcomes': [{'measure': 'Mean CGM glucose value.', 'timeFrame': 'Every 5 min for 9 hours on each study day.'}, {'measure': 'Percentage of time when CGM values are < 3.9 mmol/l.', 'timeFrame': 'Every 5 min for 9 hours on each study day.'}, {'measure': 'Percentage of time when CGM values are > 8.0 mmol/l.', 'timeFrame': 'Every 5 min for 9 hours on each study day.'}, {'measure': 'CGM standard deviation.', 'timeFrame': 'Every 5 min for 9 hours on each study day.'}, {'measure': 'Number of hypoglycemic episodes.', 'timeFrame': 'Every 5 min for 9 hours on each study day.'}, {'measure': 'Amount of insulin delivered.', 'timeFrame': 'Every 30 min for 9 hours on each study day.'}, {'measure': 'Positive Incremental Area Under the Curve', 'timeFrame': 'Every 5 min for 9 hours on each study day.'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'keywords': ['Type 1 diabetes', 'Continuous Glucose Monitoring', 'Insulin pump', 'Sensor-augmented pump', 'Continuous correction of high blood glucose'], 'conditions': ['Type 1 Diabetes']}, 'descriptionModule': {'briefSummary': 'The potential of currently available diabetes technologies could be further exploited. The investigators propose that sensor-augmented insulin pump therapy may be improved by continuous correction, i.e. continuous evaluation of the need for correction boluses. In practice, this is carried out by running the bolus calculator every 10 minutes. The glucose sensor will provide the bolus calculator with glucose input. Many times, the bolus calculator will come to the result that no insulin is needed. However, when the blood glucose is above the pre-set target value and a correction bolus is needed, an appropriate bolus is automatically delivered by the insulin pump.\n\nThe investigators hypothesize that sensor-augmented continuous correction insulin pump therapy can reduce hyperglycemia without increasing the risk of hypoglycemia in patients with type 1 diabetes.'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'healthyVolunteers': False, 'eligibilityCriteria': "Inclusion Criteria:\n\n* Age ≥ 18 years\n* T1D ≥ 3 years\n* CSII ≥ 1 year\n* HbA1c ≤ 8.0% (64 mmol/mol)\n\nExclusion Criteria:\n\n* Pregnancy or nursing\n* Hypoglycemia unawareness\n* Gastroparesis\n* Use of anti-diabetic medicine (other than insulin), corticosteroids or other drugs affecting glucose metabolism during or within 30 days prior to the study\n* Other concomitant medical or psychological condition that according to the investigator's assessment makes the patient unsuitable for study participation"}, 'identificationModule': {'nctId': 'NCT02162004', 'briefTitle': 'Continuous Correction', 'organization': {'class': 'OTHER', 'fullName': 'Hvidovre University Hospital'}, 'officialTitle': 'Sensor-Augmented Continuous Correction in Insulin Pump-Treated Type 1 Diabetes', 'orgStudyIdInfo': {'id': 'CC2014'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'Continuous correction', 'description': "The insulin pump is set to automatically deliver the patient's usual insulin basal rate. The insulin pump bolus calculator is run every 10 minutes by the attending physician. Bolus calculations are based on glucose sensor values.", 'interventionNames': ['Procedure: Continuous Correction']}, {'type': 'NO_INTERVENTION', 'label': 'Control', 'description': 'Regular sensor-augmented pump therapy.'}], 'interventions': [{'name': 'Continuous Correction', 'type': 'PROCEDURE', 'armGroupLabels': ['Continuous correction']}]}, 'contactsLocationsModule': {'locations': [{'zip': '2650', 'city': 'Hvidovre', 'country': 'Denmark', 'facility': 'Hvidovre University Hospital', 'geoPoint': {'lat': 55.64297, 'lon': 12.47708}}], 'overallOfficials': [{'name': 'Signe Schmidt, MD, PhD', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Hvidovre University Hospital'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Hvidovre University Hospital', 'class': 'OTHER'}, 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'MD', 'investigatorFullName': 'Signe Schmidt', 'investigatorAffiliation': 'Hvidovre University Hospital'}}}}