Viewing Study NCT02651558


Ignite Creation Date: 2025-12-25 @ 12:15 AM
Ignite Modification Date: 2025-12-25 @ 12:15 AM
Study NCT ID: NCT02651558
Status: COMPLETED
Last Update Posted: 2018-04-12
First Post: 2015-12-17
Is Possible Gene Therapy: False
Has Adverse Events: False

Brief Title: Optical System to Continuously Measure Arterial Blood Pressure
Sponsor:
Organization:

Raw JSON

{'hasResults': False, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NON_RANDOMIZED', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'DIAGNOSTIC', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 70}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2016-04', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2018-04', 'completionDateStruct': {'date': '2017-11-01', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2018-04-10', 'studyFirstSubmitDate': '2015-12-17', 'studyFirstSubmitQcDate': '2016-01-07', 'lastUpdatePostDateStruct': {'date': '2018-04-12', 'type': 'ACTUAL'}, 'studyFirstPostDateStruct': {'date': '2016-01-11', 'type': 'ESTIMATED'}, 'primaryCompletionDateStruct': {'date': '2017-11-01', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Error (in mmHg) between paired determinations of arterial blood pressure from an optical device against reference measurements from an arterial catheter', 'timeFrame': '24 months', 'description': 'The signals recorded by the optical blood pressure device will be retrospectively analysed (offline analysis) in order to test the hypothesis that blood pressure values as derived by the new device is comparable to blood pressure values as measured by an arterial catheter within the limits of agreement in mmHg stated by ISO 81060-2 2013.'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'conditions': ['Blood Pressure']}, 'referencesModule': {'references': [{'pmid': '32287129', 'type': 'DERIVED', 'citation': 'Ghamri Y, Proenca M, Hofmann G, Renevey P, Bonnier G, Braun F, Axis A, Lemay M, Schoettker P. Automated Pulse Oximeter Waveform Analysis to Track Changes in Blood Pressure During Anesthesia Induction: A Proof-of-Concept Study. Anesth Analg. 2020 May;130(5):1222-1233. doi: 10.1213/ANE.0000000000004678.'}]}, 'descriptionModule': {'briefSummary': 'Comparison of an optical method to continuously measure blood pressure against an invasive arterial catheter.', 'detailedDescription': "The measurement of blood pressure during anesthesia is commonly performed by the inflation of a brachial cuff providing only intermittent blood pressure measurements. In some case, it is required to add a continuous invasive monitoring of blood pressure, via the insertion of an arterial catheter. Unfortunately, the related morbidity is not negligible. To limit the consequences of such a gesture, some developments have been done in the past to allow for continuous non-invasive measurements of blood pressure during anesthesia. Unfortunately, most of these devices are subject to important limitations and constraints of use.\n\nA new system has been designed by CSEM consisting of an optical system fixed on patient's skin, absolutely non-invasive and easy to use. In order to study the reliability of this device, the investigators plan to compare its blood pressure estimates against gold-standard arterial catheter measurements during induction of general anesthesia on:\n\n* 40 patients wearing the optical system at the chest.\n* and 40 patients wearing the optical system at the fingertip"}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'minimumAge': '18 Years', 'healthyVolunteers': True, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* patient requiring the placement of an arterial catheter for general anesthesia\n* minimum of 18 years\n* written consent\n\nExclusion Criteria:\n\n* minor patient or incapable of discernment\n* patient with AIMD\n* thoracic surgery'}, 'identificationModule': {'nctId': 'NCT02651558', 'acronym': 'BP', 'briefTitle': 'Optical System to Continuously Measure Arterial Blood Pressure', 'organization': {'class': 'INDUSTRY', 'fullName': "CSEM Centre Suisse d'Electronique et de Microtechnique SA - Recherche et Developpement"}, 'officialTitle': 'Comparison of an Optical System to Continuously Measure Arterial Blood Pressure Against a Gold-standard Arterial Catheter', 'orgStudyIdInfo': {'id': 'BLOOD PRESSURE'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'OBPM 2015-MD-0022 - CHEST', 'description': 'Cohort of 30 patients undergoing general anesthesia, monitored by optical signals at the chest', 'interventionNames': ['Device: Experimental: OBPM 2015-MD-0022 - CHEST']}, {'type': 'EXPERIMENTAL', 'label': 'OBPM 2015-MD-0022 - CHEST & FINGER', 'description': 'Cohort of 10 patients undergoing general anesthesia, monitored by optical signals at the chest and at the fingertip', 'interventionNames': ['Device: Experimental: OBPM 2015-MD-0022 - CHEST & FINGER']}, {'type': 'EXPERIMENTAL', 'label': 'OBPM 2015-MD-0022 - FINGER', 'description': 'Cohort of 30 patients undergoing general anesthesia, monitored by optical signals at the fingertip', 'interventionNames': ['Device: Experimental: OBPM 2015-MD-0022 - FINGER']}], 'interventions': [{'name': 'Experimental: OBPM 2015-MD-0022 - CHEST', 'type': 'DEVICE', 'description': 'At the onset of general anesthesia:\n\n1. continuous measurements of radial arterial blood pressure values (arterial catheter, via a commercial PHILIPS IntelliVue MP50 monitor)\n2. continuous estimates of optical blood pressure values at the chest (optical blood pressure system, via Swissmedic approved OBPM measuring device 2015-MD-0022 developed by CSEM)\n\nwill be recorded.', 'armGroupLabels': ['OBPM 2015-MD-0022 - CHEST']}, {'name': 'Experimental: OBPM 2015-MD-0022 - CHEST & FINGER', 'type': 'DEVICE', 'description': 'At the onset of general anesthesia:\n\n1. continuous measurements of radial arterial blood pressure values (arterial catheter, via a commercial PHILIPS IntelliVue MP50 monitor)\n2. continuous estimates of optical blood pressure values at the chest (optical blood pressure system, via Swissmedic approved OBPM measuring device 2015-MD-0022 developed by CSEM)\n3. continuous estimates of optical blood pressure values at the fingertip (optical blood pressure system, via Swissmedic approved OBPM measuring device 2015-MD-0022 developed by CSEM)\n\nwill be recorded.', 'armGroupLabels': ['OBPM 2015-MD-0022 - CHEST & FINGER']}, {'name': 'Experimental: OBPM 2015-MD-0022 - FINGER', 'type': 'DEVICE', 'description': 'At the onset of general anesthesia:\n\n1. continuous measurements of radial arterial blood pressure values (arterial catheter, via a commercial PHILIPS IntelliVue MP50 monitor)\n2. continuous estimates of optical blood pressure values at the fingertip (optical blood pressure system, via Swissmedic approved OBPM measuring device 2015-MD-0022 developed by CSEM)\n\nwill be recorded.', 'armGroupLabels': ['OBPM 2015-MD-0022 - FINGER']}]}, 'contactsLocationsModule': {'locations': [{'city': 'Lausanne', 'country': 'Switzerland', 'facility': 'CHUV', 'geoPoint': {'lat': 46.516, 'lon': 6.63282}}], 'overallOfficials': [{'name': 'Patrick Schoettker', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'CHUV'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': "CSEM Centre Suisse d'Electronique et de Microtechnique SA - Recherche et Developpement", 'class': 'INDUSTRY'}, 'collaborators': [{'name': 'Centre Hospitalier Universitaire Vaudois', 'class': 'OTHER'}], 'responsibleParty': {'type': 'SPONSOR'}}}}