Viewing Study NCT01135095


Ignite Creation Date: 2025-12-24 @ 2:04 PM
Ignite Modification Date: 2026-01-28 @ 7:26 PM
Study NCT ID: NCT01135095
Status: COMPLETED
Last Update Posted: 2021-01-26
First Post: 2009-10-15
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: Low Dose One-Day Tc99m Protocol With a High-Efficiency Cardiac Dedicated Gamma Camera For Detection of Coronary Disease
Sponsor:
Organization:

Raw JSON

{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D002637', 'term': 'Chest Pain'}], 'ancestors': [{'id': 'D010146', 'term': 'Pain'}, {'id': 'D009461', 'term': 'Neurologic Manifestations'}, {'id': 'D012816', 'term': 'Signs and Symptoms'}, {'id': 'D013568', 'term': 'Pathological Conditions, Signs and Symptoms'}]}, 'interventionBrowseModule': {'meshes': [{'id': 'D014965', 'term': 'X-Rays'}], 'ancestors': [{'id': 'D060733', 'term': 'Electromagnetic Radiation'}, {'id': 'D055590', 'term': 'Electromagnetic Phenomena'}, {'id': 'D060328', 'term': 'Magnetic Phenomena'}, {'id': 'D055585', 'term': 'Physical Phenomena'}, {'id': 'D011827', 'term': 'Radiation'}, {'id': 'D011839', 'term': 'Radiation, Ionizing'}]}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'Andrew.einstein@columbia.edu', 'phone': '+1 212 305-4275', 'title': 'Dr. Andrew J. Einstein', 'organization': 'Department of Medicine, Cardiology Division, Columbia University Medical Center and New York Presbyterian Hospital, New York'}, 'certainAgreement': {'piSponsorEmployee': False, 'restrictiveAgreement': False}}, 'adverseEventsModule': {'eventGroups': [{'id': 'EG000', 'title': 'Low-dose Imaging', 'description': 'Low-dose versus standard dose imaging\n\nLow-dose imaging: the study is designed to assess the validity of a low dose (\\~5mSv) Tc99m one day protocol using D-SPECT standard protocol as the comparators.\n\nD-SPECT cardiac scanner: the D-SPECT system uses a solid-state detector, made of an alloy of Cadmium, Zinc, and Telluride, eliminating the need for thick crystals and large photomultiplier tubes. As a result, the system is significantly miniaturized, and ergonomically optimized to both user and patient', 'otherNumAtRisk': 101, 'otherNumAffected': 0, 'seriousNumAtRisk': 101, 'seriousNumAffected': 0}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'Summed Rest Score (SRS) Using American Heart Association 17 Segment Polar Map Model', 'denoms': [{'units': 'Participants', 'counts': [{'value': '101', 'groupId': 'OG000'}]}], 'groups': [{'id': 'OG000', 'title': 'Low-dose Imaging', 'description': 'Low-dose versus standard dose imaging\n\nLow-dose imaging: the study is designed to assess the validity of a low dose (\\~5mSv) Tc99m one day protocol using D-SPECT standard protocol as the comparators.\n\nD-SPECT cardiac scanner: the D-SPECT system uses a solid-state detector, made of an alloy of Cadmium, Zinc, and Telluride, eliminating the need for thick crystals and large photomultiplier tubes. As a result, the system is significantly miniaturized, and ergonomically optimized to both user and patient'}], 'classes': [{'title': 'Summed Rest Score Ultra-Low-Dose High-Efficiency SPECT imaging: D-SPECT camera', 'categories': [{'measurements': [{'value': '2.75', 'spread': '5.41', 'groupId': 'OG000'}]}]}, {'title': 'Summed Rest Score Standard-Low-Dose A-SPECT imaging: Siemens ECAM/Symbia T6 or Philips Forte camera', 'categories': [{'measurements': [{'value': '2.95', 'spread': '5.40', 'groupId': 'OG000'}]}]}], 'paramType': 'MEAN', 'timeFrame': '1 day', 'description': 'SRS is used to quantify presence/severity of SPECT rest myocardial perfusion defects, as assessed by visual analysis using American Heart Association (AHA) 17 segment polar map model; each segment correlates to a myocardial location. Perfusion abnormalities can be determined in relation to myocardial segment/s affected by ischemia and the perfusion defect severity scored using 0 - 4 scale for each segment (0, normal uptake; 1, mildly reduced uptake; 2, moderately reduced uptake; 3, severely reduced uptake; and 4, no uptake). SRS is calculated by summing individual scores from each of 17 segments to give an overall score between 0 and 68; a score of 0 indicates normal outcome and scores \\> 0 indicate increasingly worse outcomes as the score increases. For each patient, SRS will be compared between standard-low-dose (SLD) imaging from a conventional A-SPECT camera and ultra-low-dose (ULD) imaging from a high-efficiency D-SPECT camera, both acquired on the same day.', 'unitOfMeasure': 'score on a scale', 'dispersionType': 'Standard Deviation', 'reportingStatus': 'POSTED', 'populationDescription': 'Patients with suspected or known coronary artery disease scheduled to undergo rest-stress 1 day 99mTc-based SPECT myocardial perfusion imaging.'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'Low-dose Imaging', 'description': 'Low-dose versus standard-dose imaging\n\nLow-dose imaging: the study is designed to assess the validity of a low-dose (\\~5mSv) Tc99m one day protocol using D-SPECT standard protocol as the comparators.\n\nD-SPECT cardiac scanner: the D-SPECT system uses a solid-state detector, made of an alloy of Cadmium, Zinc, and Telluride, eliminating the need for thick crystals and large photomultiplier tubes. As a result, the system is significantly miniaturized, and ergonomically optimized to both user and patient.'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '101'}]}, {'type': 'COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '101'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '0'}]}]}], 'recruitmentDetails': "101 patients prospectively enrolled at 3 US hospital sites (Cedars-Sinai Medical Center, Oregon Heart and Vascular Institute, Brigham and Women's Hospital) between June 2010 and June 2012.", 'preAssignmentDetails': 'No post-enrollment pre-assignment significant events occurred.'}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '101', 'groupId': 'BG000'}]}], 'groups': [{'id': 'BG000', 'title': 'Low-dose Imaging', 'description': 'Low-dose versus standard dose imaging\n\nLow-dose imaging: the study is designed to assess the validity of a low dose (\\~5mSv) Tc99m one day protocol using D-SPECT standard protocol as the comparators.\n\nD-SPECT cardiac scanner: the D-SPECT system uses a solid-state detector, made of an alloy of Cadmium, Zinc, and Telluride, eliminating the need for thick crystals and large photomultiplier tubes. As a result, the system is significantly miniaturized, and ergonomically optimized to both user and patient.'}], 'measures': [{'title': 'Age, Continuous', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '101', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '63.8', 'spread': '11.3', 'groupId': 'BG000'}]}]}], 'paramType': 'MEAN', 'unitOfMeasure': 'years', 'dispersionType': 'STANDARD_DEVIATION'}, {'title': 'Sex: Female, Male', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '101', 'groupId': 'BG000'}]}], 'categories': [{'title': 'Female', 'measurements': [{'value': '47', 'groupId': 'BG000'}]}, {'title': 'Male', 'measurements': [{'value': '54', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Race and Ethnicity Not Collected', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '0', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants', 'populationDescription': 'Race and Ethnicity were not collected from any participant.'}, {'title': 'Region of Enrollment', 'classes': [{'title': 'United States', 'denoms': [{'units': 'Participants', 'counts': [{'value': '101', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '101', 'groupId': 'BG000'}]}]}], 'paramType': 'NUMBER', 'unitOfMeasure': 'participants'}, {'title': 'BMI', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '101', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '26.1', 'spread': '2.8', 'groupId': 'BG000'}]}]}], 'paramType': 'MEAN', 'unitOfMeasure': 'Kg/m^2', 'dispersionType': 'STANDARD_DEVIATION'}, {'title': 'Diabetes Mellitus', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '101', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '26', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Hypertension', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '101', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '74', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Hyperlipidemia', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '101', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '77', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Current smoker', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '101', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '13', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Family history of premature heart disease', 'classes': [{'denoms': [{'units': 'Participants', 'counts': [{'value': '101', 'groupId': 'BG000'}]}], 'categories': [{'measurements': [{'value': '31', 'groupId': 'BG000'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}], 'populationDescription': 'Patients with suspected or known coronary artery disease scheduled to undergo rest-stress 1 day 99mTc-based SPECT myocardial perfusion imaging.'}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'NA', 'maskingInfo': {'masking': 'NONE'}, 'primaryPurpose': 'DIAGNOSTIC', 'interventionModel': 'SINGLE_GROUP'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 101}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2010-06'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2021-01', 'completionDateStruct': {'date': '2013-04', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2021-01-05', 'studyFirstSubmitDate': '2009-10-15', 'resultsFirstSubmitDate': '2020-11-06', 'studyFirstSubmitQcDate': '2010-06-01', 'lastUpdatePostDateStruct': {'date': '2021-01-26', 'type': 'ACTUAL'}, 'resultsFirstSubmitQcDate': '2021-01-05', 'studyFirstPostDateStruct': {'date': '2010-06-02', 'type': 'ESTIMATED'}, 'resultsFirstPostDateStruct': {'date': '2021-01-26', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2012-06', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Summed Rest Score (SRS) Using American Heart Association 17 Segment Polar Map Model', 'timeFrame': '1 day', 'description': 'SRS is used to quantify presence/severity of SPECT rest myocardial perfusion defects, as assessed by visual analysis using American Heart Association (AHA) 17 segment polar map model; each segment correlates to a myocardial location. Perfusion abnormalities can be determined in relation to myocardial segment/s affected by ischemia and the perfusion defect severity scored using 0 - 4 scale for each segment (0, normal uptake; 1, mildly reduced uptake; 2, moderately reduced uptake; 3, severely reduced uptake; and 4, no uptake). SRS is calculated by summing individual scores from each of 17 segments to give an overall score between 0 and 68; a score of 0 indicates normal outcome and scores \\> 0 indicate increasingly worse outcomes as the score increases. For each patient, SRS will be compared between standard-low-dose (SLD) imaging from a conventional A-SPECT camera and ultra-low-dose (ULD) imaging from a high-efficiency D-SPECT camera, both acquired on the same day.'}]}, 'oversightModule': {'oversightHasDmc': False}, 'conditionsModule': {'keywords': ['Myocardial perfusion', 'Low radiation dose', 'Single photon emission computed tomography'], 'conditions': ['Chest Pain']}, 'descriptionModule': {'briefSummary': 'A prospective single clinical trial to validate the use of a low-dose (\\~5mSv) Tc-99m protocol with a high-efficiency cardiac dedicated camera (Dynamic Single Photon Emission Computed Tomography; D-SPECT) to detect myocardial perfusion abnormalities during myocardial perfusion imaging.', 'detailedDescription': 'as above'}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'maximumAge': '90 Years', 'minimumAge': '18 Years', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n1. Patient is referred to myocardial perfusion D-SPECT for clinical indications.\n2. Written informed consent is obtained by a study investigator.\n\nExclusion Criteria:\n\n1. Patient is diagnosed as having uncontrolled congestive cardiac failure or cardiogenic shock.\n2. Patient is diagnosed as having uncontrolled hypertension with resting blood pressure \\> 220 mm Hg systolic or 110 mm Hg diastolic.\n3. Patient pregnancy (known or suspected).\n4. Lack of written informed consent\n5. Prisoner status\n6. Minors under the age of 18 as coronary artery disease is generally an adult disease'}, 'identificationModule': {'nctId': 'NCT01135095', 'briefTitle': 'Low Dose One-Day Tc99m Protocol With a High-Efficiency Cardiac Dedicated Gamma Camera For Detection of Coronary Disease', 'organization': {'class': 'INDUSTRY', 'fullName': 'Spectrum Dynamics'}, 'officialTitle': 'Validation of a Low-Dose One-Day TC99m Protocol With a High-Efficiency Cardiac Dedicated Gamma Camera for Detection of Coronary Artery Disease', 'orgStudyIdInfo': {'id': 'SD-DSPECT002'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'EXPERIMENTAL', 'label': 'low-dose imaging', 'description': 'low dose versus standard dose imaging', 'interventionNames': ['Radiation: low-dose imaging']}], 'interventions': [{'name': 'low-dose imaging', 'type': 'RADIATION', 'otherNames': ['low dose imaging'], 'description': 'The study is designed to assess the validity of a low dose (\\~5mSv) Tc99m one day protocol using D-SPECT standard protocol as the comparators.\n\nD-SPECT cardiac scanner the D-SPECT system uses a solid-state detector, made of an alloy of Cadmium, Zinc, and Telluride, eliminating the need for thick crystals and large photomultiplier tubes. As a result, the system is significantly miniaturized, and ergonomically optimized to both user and patient', 'armGroupLabels': ['low-dose imaging']}]}, 'contactsLocationsModule': {'locations': [{'zip': '00000', 'city': 'Los Angeles', 'state': 'California', 'country': 'United States', 'facility': 'Cedars-Sinai Medical Center', 'geoPoint': {'lat': 34.05223, 'lon': -118.24368}}, {'zip': '00000', 'city': 'Springfield', 'state': 'Oregon', 'country': 'United States', 'facility': 'Oregon Heart and Vascular Institute', 'geoPoint': {'lat': 44.04624, 'lon': -123.02203}}], 'overallOfficials': [{'name': 'Andrew Einstein, MD,PHD', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Columbia University Medical Center, Department of Medicine, Division of Cardiology'}, {'name': 'Dan Berman, MD', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Cedars-Sinai Medical Center'}]}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Spectrum Dynamics', 'class': 'INDUSTRY'}, 'collaborators': [{'name': 'PeaceHealth Medical Group', 'class': 'OTHER'}, {'name': "Brigham and Women's Hospital", 'class': 'OTHER'}, {'name': 'Cedars-Sinai Medical Center', 'class': 'OTHER'}], 'responsibleParty': {'type': 'SPONSOR'}}}}