Viewing Study NCT02867995


Ignite Creation Date: 2025-12-24 @ 2:08 PM
Ignite Modification Date: 2026-04-05 @ 5:51 AM
Study NCT ID: NCT02867995
Status: COMPLETED
Last Update Posted: 2019-02-15
First Post: 2016-08-07
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: Efficacy of Glaucoma Drop Aids in Medication Compliance in the Patient Population at Boston Medical Center
Sponsor:
Organization:

Raw JSON

{'hasResults': True, 'derivedSection': {'miscInfoModule': {'versionHolder': '2025-12-24'}, 'conditionBrowseModule': {'meshes': [{'id': 'D005901', 'term': 'Glaucoma'}], 'ancestors': [{'id': 'D009798', 'term': 'Ocular Hypertension'}, {'id': 'D005128', 'term': 'Eye Diseases'}]}}, 'resultsSection': {'moreInfoModule': {'pointOfContact': {'email': 'Manishi.Desai@bmc.org', 'phone': '671-414-8806', 'title': 'Dr. Manishi Desai', 'organization': 'Boston Medical Center'}, 'certainAgreement': {'piSponsorEmployee': True}}, 'adverseEventsModule': {'timeFrame': '6 weeks', 'eventGroups': [{'id': 'EG000', 'title': 'Control', 'description': 'No glaucoma drop aid received- control', 'otherNumAtRisk': 9, 'deathsNumAtRisk': 9, 'otherNumAffected': 0, 'seriousNumAtRisk': 9, 'deathsNumAffected': 0, 'seriousNumAffected': 0}, {'id': 'EG001', 'title': 'Eye Drop Aids', 'description': 'Participants could be placed into one of the drop aid groups (Fabrication Autodrop Eye Drop Guide,Owen Mumford OP 6100 Autosqueeze, or the Simply Touch Eye Drop Applicator)\n\nEye Drop Aid: Fabrication Autodrop Eye Drop Guide,Owen Mumford OP 6100 Autosqueeze, and the Simply Touch Eye Drop Applicator', 'otherNumAtRisk': 30, 'deathsNumAtRisk': 30, 'otherNumAffected': 0, 'seriousNumAtRisk': 30, 'deathsNumAffected': 0, 'seriousNumAffected': 0}], 'frequencyThreshold': '0'}, 'outcomeMeasuresModule': {'outcomeMeasures': [{'type': 'PRIMARY', 'title': 'Number of Participants Assessed for Intraocular Pressure Change', 'denoms': [{'units': 'Participants', 'counts': [{'value': '9', 'groupId': 'OG000'}, {'value': '27', 'groupId': 'OG001'}]}], 'groups': [{'id': 'OG000', 'title': 'Control', 'description': 'No glaucoma drop aid control'}, {'id': 'OG001', 'title': 'Eye Drop Aids', 'description': 'Participants could be placed into one of the drop aid groups (Fabrication Autodrop Eye Drop Guide,Owen Mumford OP 6100 Autosqueeze, or the Simply Touch Eye Drop Applicator)\n\nEye Drop Aid: Fabrication Autodrop Eye Drop Guide,Owen Mumford OP 6100 Autosqueeze, and the Simply Touch Eye Drop Applicator'}], 'classes': [{'title': 'Significant increase in IOP', 'categories': [{'measurements': [{'value': '0', 'groupId': 'OG000'}, {'value': '4', 'groupId': 'OG001'}]}]}, {'title': 'Significant decrease in IOP', 'categories': [{'measurements': [{'value': '4', 'groupId': 'OG000'}, {'value': '8', 'groupId': 'OG001'}]}]}, {'title': 'No change in IOP', 'categories': [{'measurements': [{'value': '5', 'groupId': 'OG000'}, {'value': '15', 'groupId': 'OG001'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'timeFrame': 'baseline and 6 weeks', 'description': 'Intraocular pressure (IOP) is measured by Goldman applanation in patients and is expressed in mmHg. The IOP, which is a routine check in the ophthalmic exam, was measured in the eye drop aid group prior to starting drop aid use and at six weeks while using drop aids. IOP was measured at baseline and at 6 weeks in the control group. A significant increase in IOP is defined as an increase of 4 mmHg or more, a significant decreases in IOP is defined as a decrease of 4mmHg or more. No significant change in the IOP is a change between 1-3 mmHg.', 'unitOfMeasure': 'Participants', 'reportingStatus': 'POSTED'}, {'type': 'SECONDARY', 'title': 'Number of Participants Stratified by the Number of Times Eye Was Missed When Inserting Eye Drops', 'denoms': [{'units': 'Participants', 'counts': [{'value': '9', 'groupId': 'OG000'}, {'value': '27', 'groupId': 'OG001'}]}], 'groups': [{'id': 'OG000', 'title': 'Control', 'description': 'No glaucoma drop aid control'}, {'id': 'OG001', 'title': 'Eye Drop Aids', 'description': 'Participants could be placed into one of the drop aid groups (Fabrication Autodrop Eye Drop Guide,Owen Mumford OP 6100 Autosqueeze, or the Simply Touch Eye Drop Applicator)\n\nEye Drop Aid: Fabrication Autodrop Eye Drop Guide,Owen Mumford OP 6100 Autosqueeze, and the Simply Touch Eye Drop Applicator'}], 'classes': [{'title': 'Missed inserting eye drops 0 times', 'categories': [{'measurements': [{'value': '3', 'groupId': 'OG000'}, {'value': '10', 'groupId': 'OG001'}]}]}, {'title': 'Missed inserting eye drops 1 times', 'categories': [{'measurements': [{'value': '5', 'groupId': 'OG000'}, {'value': '8', 'groupId': 'OG001'}]}]}, {'title': 'Missed inserting eye drops 2 times', 'categories': [{'measurements': [{'value': '0', 'groupId': 'OG000'}, {'value': '1', 'groupId': 'OG001'}]}]}, {'title': 'Missed inserting eye drops 3 or more times', 'categories': [{'measurements': [{'value': '1', 'groupId': 'OG000'}, {'value': '2', 'groupId': 'OG001'}]}]}, {'title': 'No Data Available', 'categories': [{'measurements': [{'value': '0', 'groupId': 'OG000'}, {'value': '6', 'groupId': 'OG001'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'timeFrame': '6 weeks', 'description': 'A question on the six week survey asked approximately how often the participant missed their eye when inserting eye drops. Response options included: missed inserting eye drops 0 times, missed inserting eye drops 1 time, missed inserting eye drops 2 times, or missed inserting eye drops 3 or more times.', 'unitOfMeasure': 'Participants', 'reportingStatus': 'POSTED', 'populationDescription': 'Participants include those who were compliant with their drop aid device throughout the length of their medication bottle, as well as those who were non-compliant with their device group.'}, {'type': 'SECONDARY', 'title': 'Satisfaction With Eye Drop Aid', 'denoms': [{'units': 'Participants', 'counts': [{'value': '7', 'groupId': 'OG000'}, {'value': '8', 'groupId': 'OG001'}, {'value': '9', 'groupId': 'OG002'}, {'value': '9', 'groupId': 'OG003'}]}], 'groups': [{'id': 'OG000', 'title': 'AutoDrop', 'description': 'Patients placed in this group were given the Fabrication Autodrop Eye Drop Guide to instill their eye drops with'}, {'id': 'OG001', 'title': 'Autosqueeze', 'description': 'Participants placed in this group were given the Owen Mumford OP 6100 Autosqueeze in order to instill their eye drops.'}, {'id': 'OG002', 'title': 'Simply Touch', 'description': 'Participants placed in this group were given the Simply Touch Eye Drop Applicator in order to instill their eye drops.'}, {'id': 'OG003', 'title': 'Control', 'description': 'No glaucoma drop aid control'}], 'classes': [{'title': 'Liked Drop Aid', 'categories': [{'measurements': [{'value': '3', 'groupId': 'OG000'}, {'value': '6', 'groupId': 'OG001'}, {'value': '3', 'groupId': 'OG002'}, {'value': '0', 'groupId': 'OG003'}]}]}, {'title': 'Did Not Like Drop Aid', 'categories': [{'measurements': [{'value': '4', 'groupId': 'OG000'}, {'value': '2', 'groupId': 'OG001'}, {'value': '4', 'groupId': 'OG002'}, {'value': '0', 'groupId': 'OG003'}]}]}, {'title': 'Did not use Drop Aid', 'categories': [{'measurements': [{'value': '0', 'groupId': 'OG000'}, {'value': '0', 'groupId': 'OG001'}, {'value': '2', 'groupId': 'OG002'}, {'value': '9', 'groupId': 'OG003'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'timeFrame': '6 weeks', 'description': 'A question on the six week survey asked if the participant liked the eye drop aid. Response options included: liked the drop aid long term, did not like the drop aid, or did not use a drop aid. Results were stratified by the three drop aid types (Fabrication Autodrop Eye Drop Guide, Owen Mumford OP 6100 Autosqueeze, or the Simply Touch Eye Drop Applicator).', 'unitOfMeasure': 'Participants', 'reportingStatus': 'POSTED', 'populationDescription': 'Participants include all enrolled patients who completed the study. The drop aid group was stratified into the three types of aids- AutoDrop, Autosqueeze, and Simply Touch.'}, {'type': 'SECONDARY', 'title': 'Intent to Use Eye Drop Aid Long Term', 'denoms': [{'units': 'Participants', 'counts': [{'value': '10', 'groupId': 'OG000'}, {'value': '8', 'groupId': 'OG001'}, {'value': '9', 'groupId': 'OG002'}, {'value': '9', 'groupId': 'OG003'}]}], 'groups': [{'id': 'OG000', 'title': 'AutoDrop', 'description': 'Patients placed in this group were given the Fabrication Autodrop Eye Drop Guide to instill their eye drops with'}, {'id': 'OG001', 'title': 'Autosqueeze', 'description': 'Participants placed in this group were given the Owen Mumford OP 6100 Autosqueeze in order to instill their eye drops.'}, {'id': 'OG002', 'title': 'Simply Touch', 'description': 'Participants placed in this group were given the Simply Touch Eye Drop Applicator in order to instill their eye drops.'}, {'id': 'OG003', 'title': 'Control', 'description': 'No glaucoma drop aid control'}], 'classes': [{'title': 'Would use Drop Aid long term', 'categories': [{'measurements': [{'value': '9', 'groupId': 'OG000'}, {'value': '6', 'groupId': 'OG001'}, {'value': '3', 'groupId': 'OG002'}, {'value': '0', 'groupId': 'OG003'}]}]}, {'title': 'Would not use Drop Aid long term', 'categories': [{'measurements': [{'value': '1', 'groupId': 'OG000'}, {'value': '2', 'groupId': 'OG001'}, {'value': '4', 'groupId': 'OG002'}, {'value': '0', 'groupId': 'OG003'}]}]}, {'title': 'Did not use Drop Aid', 'categories': [{'measurements': [{'value': '0', 'groupId': 'OG000'}, {'value': '0', 'groupId': 'OG001'}, {'value': '2', 'groupId': 'OG002'}, {'value': '9', 'groupId': 'OG003'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'timeFrame': '6 weeks', 'description': 'A question on the six week survey asked if the participant intended to use the eye drop aid long term. Response options included: would use the drop aid long term, would not use the drop aid long term, or did not use a drop aid. Results were stratified by the three drop aid types (Fabrication Autodrop Eye Drop Guide, Owen Mumford OP 6100 Autosqueeze, or the Simply Touch Eye Drop Applicator).', 'unitOfMeasure': 'Participants', 'reportingStatus': 'POSTED', 'populationDescription': 'Participants include all enrolled patients who completed the study. The drop aid group was stratified into the three types of aids- AutoDrop, Autosqueeze, and Simply Touch.'}]}, 'participantFlowModule': {'groups': [{'id': 'FG000', 'title': 'Control', 'description': 'No glaucoma drop aid control'}, {'id': 'FG001', 'title': 'Eye Drop Aids', 'description': 'Participants could be placed into one of the drop aid groups (Fabrication Autodrop Eye Drop Guide,Owen Mumford OP 6100 Autosqueeze, or the Simply Touch Eye Drop Applicator)\n\nEye Drop Aid: Fabrication Autodrop Eye Drop Guide,Owen Mumford OP 6100 Autosqueeze, and the Simply Touch Eye Drop Applicator'}], 'periods': [{'title': 'Overall Study', 'milestones': [{'type': 'STARTED', 'achievements': [{'comment': 'Total patients consented', 'groupId': 'FG000', 'numSubjects': '9'}, {'comment': 'Total patients consented', 'groupId': 'FG001', 'numSubjects': '30'}]}, {'type': 'COMPLETED', 'achievements': [{'comment': 'Total patients completed', 'groupId': 'FG000', 'numSubjects': '9'}, {'comment': 'Total patients completed', 'groupId': 'FG001', 'numSubjects': '27'}]}, {'type': 'NOT COMPLETED', 'achievements': [{'groupId': 'FG000', 'numSubjects': '0'}, {'groupId': 'FG001', 'numSubjects': '3'}]}], 'dropWithdraws': [{'type': 'Withdrawal by Subject', 'reasons': [{'groupId': 'FG000', 'numSubjects': '0'}, {'groupId': 'FG001', 'numSubjects': '1'}]}, {'type': 'Lost to Follow-up', 'reasons': [{'groupId': 'FG000', 'numSubjects': '0'}, {'groupId': 'FG001', 'numSubjects': '2'}]}]}]}, 'baselineCharacteristicsModule': {'denoms': [{'units': 'Participants', 'counts': [{'value': '9', 'groupId': 'BG000'}, {'value': '30', 'groupId': 'BG001'}, {'value': '39', 'groupId': 'BG002'}]}], 'groups': [{'id': 'BG000', 'title': 'No Drop Aid', 'description': 'No glaucoma drop aid received- control'}, {'id': 'BG001', 'title': 'Drop Aid', 'description': 'Participants could be placed into one of the drop aid groups (Fabrication Autodrop Eye Drop Guide,Owen Mumford OP 6100 Autosqueeze, or the Simply Touch Eye Drop Applicator)\n\nEye Drop Aid: Fabrication Autodrop Eye Drop Guide,Owen Mumford OP 6100 Autosqueeze, and the Simply Touch Eye Drop Applicator'}, {'id': 'BG002', 'title': 'Total', 'description': 'Total of all reporting groups'}], 'measures': [{'title': 'Age, Categorical', 'classes': [{'categories': [{'title': '<=18 years', 'measurements': [{'value': '0', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '0', 'groupId': 'BG002'}]}, {'title': 'Between 18 and 65 years', 'measurements': [{'value': '2', 'groupId': 'BG000'}, {'value': '17', 'groupId': 'BG001'}, {'value': '19', 'groupId': 'BG002'}]}, {'title': '>=65 years', 'measurements': [{'value': '7', 'groupId': 'BG000'}, {'value': '13', 'groupId': 'BG001'}, {'value': '20', 'groupId': 'BG002'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Sex: Female, Male', 'classes': [{'categories': [{'title': 'Female', 'measurements': [{'value': '2', 'groupId': 'BG000'}, {'value': '16', 'groupId': 'BG001'}, {'value': '18', 'groupId': 'BG002'}]}, {'title': 'Male', 'measurements': [{'value': '7', 'groupId': 'BG000'}, {'value': '14', 'groupId': 'BG001'}, {'value': '21', 'groupId': 'BG002'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Ethnicity (NIH/OMB)', 'classes': [{'categories': [{'title': 'Hispanic or Latino', 'measurements': [{'value': '0', 'groupId': 'BG000'}, {'value': '1', 'groupId': 'BG001'}, {'value': '1', 'groupId': 'BG002'}]}, {'title': 'Not Hispanic or Latino', 'measurements': [{'value': '9', 'groupId': 'BG000'}, {'value': '29', 'groupId': 'BG001'}, {'value': '38', 'groupId': 'BG002'}]}, {'title': 'Unknown or Not Reported', 'measurements': [{'value': '0', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '0', 'groupId': 'BG002'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Race (NIH/OMB)', 'classes': [{'categories': [{'title': 'American Indian or Alaska Native', 'measurements': [{'value': '0', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '0', 'groupId': 'BG002'}]}, {'title': 'Asian', 'measurements': [{'value': '1', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '1', 'groupId': 'BG002'}]}, {'title': 'Native Hawaiian or Other Pacific Islander', 'measurements': [{'value': '0', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '0', 'groupId': 'BG002'}]}, {'title': 'Black or African American', 'measurements': [{'value': '5', 'groupId': 'BG000'}, {'value': '21', 'groupId': 'BG001'}, {'value': '26', 'groupId': 'BG002'}]}, {'title': 'White', 'measurements': [{'value': '1', 'groupId': 'BG000'}, {'value': '5', 'groupId': 'BG001'}, {'value': '6', 'groupId': 'BG002'}]}, {'title': 'More than one race', 'measurements': [{'value': '0', 'groupId': 'BG000'}, {'value': '0', 'groupId': 'BG001'}, {'value': '0', 'groupId': 'BG002'}]}, {'title': 'Unknown or Not Reported', 'measurements': [{'value': '2', 'groupId': 'BG000'}, {'value': '4', 'groupId': 'BG001'}, {'value': '6', 'groupId': 'BG002'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}, {'title': 'Region of Enrollment', 'classes': [{'title': 'United States', 'categories': [{'measurements': [{'value': '9', 'groupId': 'BG000'}, {'value': '30', 'groupId': 'BG001'}, {'value': '39', 'groupId': 'BG002'}]}]}], 'paramType': 'NUMBER', 'unitOfMeasure': 'participants'}, {'title': 'Glaucoma', 'classes': [{'categories': [{'measurements': [{'value': '9', 'groupId': 'BG000'}, {'value': '30', 'groupId': 'BG001'}, {'value': '39', 'groupId': 'BG002'}]}]}], 'paramType': 'COUNT_OF_PARTICIPANTS', 'unitOfMeasure': 'Participants'}]}}, 'documentSection': {'largeDocumentModule': {'largeDocs': [{'date': '2017-11-16', 'size': 981388, 'label': 'Study Protocol and Statistical Analysis Plan', 'hasIcf': False, 'hasSap': True, 'filename': 'Prot_SAP_000.pdf', 'typeAbbrev': 'Prot_SAP', 'uploadDate': '2019-01-24T15:31', 'hasProtocol': True}]}}, 'protocolSection': {'designModule': {'phases': ['NA'], 'studyType': 'INTERVENTIONAL', 'designInfo': {'allocation': 'RANDOMIZED', 'maskingInfo': {'masking': 'SINGLE', 'whoMasked': ['PARTICIPANT']}, 'primaryPurpose': 'SUPPORTIVE_CARE', 'interventionModel': 'PARALLEL'}, 'enrollmentInfo': {'type': 'ACTUAL', 'count': 39}}, 'statusModule': {'overallStatus': 'COMPLETED', 'startDateStruct': {'date': '2017-03-23', 'type': 'ACTUAL'}, 'expandedAccessInfo': {'hasExpandedAccess': False}, 'statusVerifiedDate': '2019-01', 'completionDateStruct': {'date': '2018-03-30', 'type': 'ACTUAL'}, 'lastUpdateSubmitDate': '2019-01-24', 'studyFirstSubmitDate': '2016-08-07', 'resultsFirstSubmitDate': '2018-12-11', 'studyFirstSubmitQcDate': '2016-08-13', 'lastUpdatePostDateStruct': {'date': '2019-02-15', 'type': 'ACTUAL'}, 'resultsFirstSubmitQcDate': '2019-01-24', 'studyFirstPostDateStruct': {'date': '2016-08-16', 'type': 'ESTIMATED'}, 'resultsFirstPostDateStruct': {'date': '2019-02-15', 'type': 'ACTUAL'}, 'primaryCompletionDateStruct': {'date': '2018-03-30', 'type': 'ACTUAL'}}, 'outcomesModule': {'primaryOutcomes': [{'measure': 'Number of Participants Assessed for Intraocular Pressure Change', 'timeFrame': 'baseline and 6 weeks', 'description': 'Intraocular pressure (IOP) is measured by Goldman applanation in patients and is expressed in mmHg. The IOP, which is a routine check in the ophthalmic exam, was measured in the eye drop aid group prior to starting drop aid use and at six weeks while using drop aids. IOP was measured at baseline and at 6 weeks in the control group. A significant increase in IOP is defined as an increase of 4 mmHg or more, a significant decreases in IOP is defined as a decrease of 4mmHg or more. No significant change in the IOP is a change between 1-3 mmHg.'}], 'secondaryOutcomes': [{'measure': 'Number of Participants Stratified by the Number of Times Eye Was Missed When Inserting Eye Drops', 'timeFrame': '6 weeks', 'description': 'A question on the six week survey asked approximately how often the participant missed their eye when inserting eye drops. Response options included: missed inserting eye drops 0 times, missed inserting eye drops 1 time, missed inserting eye drops 2 times, or missed inserting eye drops 3 or more times.'}, {'measure': 'Satisfaction With Eye Drop Aid', 'timeFrame': '6 weeks', 'description': 'A question on the six week survey asked if the participant liked the eye drop aid. Response options included: liked the drop aid long term, did not like the drop aid, or did not use a drop aid. Results were stratified by the three drop aid types (Fabrication Autodrop Eye Drop Guide, Owen Mumford OP 6100 Autosqueeze, or the Simply Touch Eye Drop Applicator).'}, {'measure': 'Intent to Use Eye Drop Aid Long Term', 'timeFrame': '6 weeks', 'description': 'A question on the six week survey asked if the participant intended to use the eye drop aid long term. Response options included: would use the drop aid long term, would not use the drop aid long term, or did not use a drop aid. Results were stratified by the three drop aid types (Fabrication Autodrop Eye Drop Guide, Owen Mumford OP 6100 Autosqueeze, or the Simply Touch Eye Drop Applicator).'}]}, 'oversightModule': {'isUsExport': False, 'oversightHasDmc': True, 'isFdaRegulatedDrug': False, 'isFdaRegulatedDevice': True}, 'conditionsModule': {'keywords': ['glaucoma drop aid'], 'conditions': ['Glaucoma']}, 'referencesModule': {'references': [{'pmid': '16049530', 'type': 'BACKGROUND', 'citation': 'Salyani A, Birt C. Evaluation of an eye drop guide to aid self-administration by patients experienced with topical use of glaucoma medication. Can J Ophthalmol. 2005 Apr;40(2):170-4. doi: 10.1016/S0008-4182(05)80028-6.'}, {'pmid': '18344762', 'type': 'BACKGROUND', 'citation': 'Ghate D, Edelhauser HF. Barriers to glaucoma drug delivery. J Glaucoma. 2008 Mar;17(2):147-56. doi: 10.1097/IJG.0b013e31814b990d.'}, {'pmid': '1596593', 'type': 'BACKGROUND', 'citation': 'Rivers PH. Compliance aids--do they work? Drugs Aging. 1992 Mar-Apr;2(2):103-11. doi: 10.2165/00002512-199202020-00004.'}]}, 'descriptionModule': {'briefSummary': 'The purpose of this study is to determine whether glaucoma drop aids will be cost-effective in delivery of ophthalmic medications by improving medication compliance, visual function, and even decreasing medication waste in the patient population at Boston Medical Center (BMC).', 'detailedDescription': "Patients being treated for their glaucoma at BMC's Yawkey Eye Clinic will be selected according to the inclusion and exclusion criteria. The three drop aids used in this study will be the Fabrication Autodrop Eye Drop Guide, Owen Mumford OP 6100 Autosqueeze, and the Simply Touch Eye Drop Applicator. Patients will be randomly placed on one of these drops aids for a total of 3 study groups or the no drop aid control, for a total of 4 groups. Prior to use of the drop aid, patients will be instructed on how to use the drop aid by a resident physician and a pre- intervention intraocular pressure check will be performed by the resident physician using an applicator. Intraocular pressure is the only adjustable risk factor for glaucoma; thus, glaucoma treatments slow progression of glaucoma by reducing intraocular pressure. In addition, patients will be requested to deliver their drops with the drop aid with every use. Furthermore, each patient will record the number of days taken to complete the glaucoma medication bottle while using the drop aid. At the 3 and 6 week marks, the patient will fill out a satisfaction survey. Patients will need to return to the clinic at the 6 week mark and can fill out the satisfaction survey at the clinic in addition to checking the intraocular pressure post-intervention. Thus, the number of subject contact will be two, pre and post-intervention, the duration of participation for each subject will be 6 weeks, and the patient will also be required to fill out two satisfaction surveys. The effectiveness of the drop aids will be compared to the two controls and measured with any changes in intraocular pressure readings, length of time to medication completion, and patient satisfaction according to the surveys."}, 'eligibilityModule': {'sex': 'ALL', 'stdAges': ['ADULT', 'OLDER_ADULT'], 'maximumAge': '89 Years', 'minimumAge': '18 Years', 'healthyVolunteers': False, 'eligibilityCriteria': 'Inclusion Criteria:\n\n* age 18 years or greater\n* Currently on the same topical medication for treatment of glaucoma for a minimum of two months\n* Patient of Boston University eye Associates\n* Agrees to use the drop aid with each delivery, return to the clinic after 6 weeks of using the drop aid, document completion of medication drops and fill out survey at the end of the 6 weeks\n\nExclusion Criteria:\n\n* Less than age 18 years\n* Changes glaucoma medication within the past two month or recent glaucoma surgery\n* Older than 89 years of age\n* Not a patient of the Boston University eye associate'}, 'identificationModule': {'nctId': 'NCT02867995', 'briefTitle': 'Efficacy of Glaucoma Drop Aids in Medication Compliance in the Patient Population at Boston Medical Center', 'organization': {'class': 'OTHER', 'fullName': 'Boston Medical Center'}, 'officialTitle': 'Efficacy of Glaucoma Drop Aids in Medication Compliance in the Patient Population at Boston Medical Center', 'orgStudyIdInfo': {'id': 'H-34905'}}, 'armsInterventionsModule': {'armGroups': [{'type': 'NO_INTERVENTION', 'label': 'Control', 'description': 'No glaucoma drop aid control'}, {'type': 'ACTIVE_COMPARATOR', 'label': 'Eye Drop Aids', 'description': 'Participants could be placed into one of the drop aid groups (Fabrication Autodrop Eye Drop Guide,Owen Mumford OP 6100 Autosqueeze, or the Simply Touch Eye Drop Applicator)', 'interventionNames': ['Device: Eye Drop Aid']}], 'interventions': [{'name': 'Eye Drop Aid', 'type': 'DEVICE', 'description': 'Fabrication Autodrop Eye Drop Guide,Owen Mumford OP 6100 Autosqueeze, and the Simply Touch Eye Drop Applicator', 'armGroupLabels': ['Eye Drop Aids']}]}, 'contactsLocationsModule': {'locations': [{'zip': '02118', 'city': 'Boston', 'state': 'Massachusetts', 'country': 'United States', 'facility': 'Boston Medical Center', 'geoPoint': {'lat': 42.35843, 'lon': -71.05977}}], 'overallOfficials': [{'name': 'Manishi Desai, MD', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Boston Medical Center'}, {'name': 'Haben Kefella, MD', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Boston Medical Center'}, {'name': 'Avni Badami, MD', 'role': 'PRINCIPAL_INVESTIGATOR', 'affiliation': 'Boston Medical Center'}]}, 'ipdSharingStatementModule': {'ipdSharing': 'UNDECIDED'}, 'sponsorCollaboratorsModule': {'leadSponsor': {'name': 'Boston Medical Center', 'class': 'OTHER'}, 'responsibleParty': {'type': 'PRINCIPAL_INVESTIGATOR', 'investigatorTitle': 'Faculty Sponsor', 'investigatorFullName': 'Manishi Desai', 'investigatorAffiliation': 'Boston Medical Center'}}}}